Home | Applications | Solutions | Blogs | About Us | Contact Us
Availability: | |
---|---|
Quantity: | |
The 200W LRS-200 AC to DC Single Output Power Supply is designed to deliver consistent power with flexible specifications, addressing the needs of both standard and specialized setups. Its core advantage lies in balancing performance and adaptability, supported by rigorous quality control and industry-leading standards.
Key technical specs include a wide input voltage range of 85~264VAC (50/60Hz) and compatibility with 120~370VDC input, enabling seamless use across global power grids—from 110VAC in North America to 220VAC in Europe and Asia. On the output side, the unit offers 12V, 24V, 36V, and 48V DC voltage options, paired with rated currents of 16.7A, 8.4A, 5.6A, and 4.2A respectively, all delivering a stable 200W rated power.
With an impressive efficiency of up to 88%, this power supply minimizes energy waste and heat generation, reducing long-term operational costs. It maintains ultra-low ripple and noise of 50mVp-p (measured at 20MHz bandwidth with 0.1μF + 47μF capacitors), ensuring clean power for sensitive electronics. The 200W LRS-200 AC to DC Single Output Power Supply also complies with strict safety and EMC standards, including UL60950-1, CE EN61558-2-16, and FCC Part15 Class B, guaranteeing compatibility in global markets.
Physically, the unit features a compact design—215mm×115mm×35mm (L×W×H)—and weighs just 0.75Kg, making it easy to install in space-constrained environments like control cabinets, LED fixtures, and equipment racks.
The 200W LRS-200 AC to DC Single Output Power Supply achieves efficiency levels of 85%~88%, with the 24V model reaching the maximum 88%. This high efficiency reduces electricity consumption—critical for 24/7 operations such as industrial machinery or data center auxiliary equipment—and lowers cooling requirements, extending the lifespan of both the power supply and connected devices. For businesses, this translates to significant long-term cost savings on energy bills.
Equipped with a 85~264VAC universal input (50/60Hz) and 120~370VDC DC input support, the 200W LRS-200 eliminates the need for additional voltage converters when used in different regions. This feature is ideal for multinational companies or equipment manufacturers, as the same power supply can be integrated into products sold globally, simplifying inventory management and reducing production complexity.
This power supply integrates comprehensive protection features to safeguard both the unit and connected devices. It offers overload protection (120%~150% rated load, auto-recovery), overvoltage protection (115%~130% rated output), and short-circuit protection (continuous current limiting, auto-recovery). These mechanisms prevent damage from unexpected electrical faults, ensuring uninterrupted operation in mission-critical applications like medical equipment or security systems.
With a ripple and noise level of just 50mVp-p, the 200W LRS-200 AC-DC unit delivers ultra-clean power. This is essential for sensitive devices such as LED displays (prevents flickering), audio equipment (avoids interference), and precision sensors (ensures accurate data collection). The low noise design also reduces electromagnetic interference (EMI), complying with FCC Part15 Class B standards to avoid disrupting nearby electronics.
The LRS-200 200W power supply features a rugged metal case that resists impact and corrosion, while its compact size (215mm×115mm×35mm) saves space in installation environments. It operates reliably in a wide temperature range of -20℃~+70℃ and humidity of 20%~90%RH (non-condensing), and can withstand vibration of 10~500Hz, 1.5G (10 minutes per axis, 60 minutes total). This durability makes it suitable for harsh industrial and outdoor-adjacent setups.
SPECIFICATIONS | |||||||||
OUTPUT | |||||||||
Model | S-100-3 | S-100-5 | S-100-7.5 | S-100-12 | S-100-15 | S-100-18 | S-100-24 | S-100-27 | S-100-48 |
DC Voltage | 3V | 5V | 7.5V | 12V | 15V | 18V | 24V | 27V | 48V |
Rated Current | 20A | 20A | 13.6A | 8.5A | 6.7A | 5.6A | 4.5A | 3.7A | 2A |
Current Range | 0-20A | 0-20A | 0-13.6A | 0-8.5A | 0-6.7A | 0-5.6A | 0-4.5A | 0-3.7A | 0-2A |
Rated Power | 60W | 100W | 102W | 102W | 100.5W | 100.8W | 108W | 99.9W | 96W |
Ripple & Noise | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p |
Voltage Adj. Range | -5%;+10% | -5%;+10% | ±10% | ±10% | ±10% | ±10% | ±10% | -4%;+18% | ±10% |
Voltage Tolerance | ±2% | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% | ±1% |
Setup, Rise, Hold Up Time | 200ms,80ms,20ms at full load | ||||||||
INPUT | |||||||||
Voltage Range | 85~132VAC/180~264VAC selected by switch 47~63Hz; 255~370VDC | ||||||||
AC Current | 2.4A/115V 1.2A/230V | ||||||||
Efficiency | 70% | 78% | 80% | 81% | 81% | 82% | 84% | 84% | 84% |
Inrush Current | Cold start 30A/115V 60A/230V | ||||||||
Leakage Current | <1mA/240VAC | ||||||||
PROTECTION | |||||||||
Over Load | 135%~165% | ||||||||
Protection type: Shut down o/p voltage, recovers automatically after fault condition is removed. | |||||||||
ENVIRONMENT | |||||||||
Working Temp., Humidity | -10℃~+60℃; 20%~90%RH | ||||||||
Storage Temp., Humidity | -20℃~+85℃; 10%~95%RH | ||||||||
Vibration | 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes | ||||||||
SAFETY | |||||||||
Withstand Voltage | I/P-O/P: 1.5KVAC I/P-FG: 1.5KVAC O/P-FG: 0.5KVAC | ||||||||
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG100M Ohms/500VDC | ||||||||
STANDARD | |||||||||
Safety Standard | Design refer to UL1012 | ||||||||
EMC Standard | Design refer to FCC Part15 J Conduction Class B | ||||||||
OTHERS | |||||||||
Dimension | 199*98*38mm (L*W*H) | ||||||||
Weight | 0.62Kg | ||||||||
Packing | 30pcs/18.6Kg/0.72CUFT | ||||||||
NOTE | |||||||||
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation |